Bolted Steel Tank Systems · Water, Wastewater & Industrial

Engineered storage. Configured to your spec.

Bolted fusion-bonded epoxy and stainless steel tanks for water, wastewater, and industrial service. Configure capacity, coating, foundation, and accessories below and get an instant budget number — refined by our engineering team within 24 hours.

Looking for a temporary or shop-fabricated tank instead? Switch to the Modular / Shop-Fabricated (EnviroBox) configurator →

5K–5MG
CAPACITY RANGE
3K+
TANKS INSTALLED
USA
STOCKED STEEL
24h
QUOTE TURNAROUND
Aluminum geodesic dome-roof bolted steel storage tank installed at an industrial site under a clear blue sky
Permanent Storage Solutions · Instant Pricing

Build your permanent tank. See the number.

For field-erected, bolted, welded, and concrete vessels engineered for the long haul. Configure tank offering, dimensions, service, foundation, roof, and accessories — the summary panel calculates a real budget number live, refined by our engineering team within 24 hours of submission. Need a temporary or shop-fabricated modular tank instead? Use the Modular / Shop-Fabricated (EnviroBox) configurator →

1
Tank Offering
Material System
2
Service / Application
Stored Product
3
Dimensions
Diameter × Height
4
Roof, Foundation & Nozzles
Structure
5
Accessories & Appurtenances
Pick & Add
Select an accessory above to see specification details and unit pricing.
Accessories Added
0 selected
No accessories yet. Pick from the list above — add as many as you need.
6
Project Context
Location & Schedule
Tank Offerings

Two offerings. One source.

Bolted fusion-bonded epoxy for water and process service. Stainless steel for aggressive chemistries, food-grade, or chloride-bearing duty. Pick the offering that matches your service, then build the quote below.

AWWA D103

Bolted Fusion-Bonded Epoxy

FBE Powder Coated · Carbon Steel

Shop-applied epoxy powder fused to carbon steel panels at 425°F. Reliable barrier at moderate cost. NSF 61 certified variants for potable water. Workhorse construction for water, raw water, and process duty.

  • Capacity5K – 5MG
  • ServiceWater / Process / Storage
  • StandardAWWA D103, NSF 61
  • Service Life20–30 years
Build FBE Quote →
ASTM A240

Bolted Stainless Steel

Type 304 / Type 316 · Bare

304 for food-grade and general chemical service. 316 for chloride-bearing, brine, biopharma, or aggressive process duty. No coating required — the passive layer is the protection. Premium first cost, lowest lifecycle cost.

  • Capacity5K – 5MG
  • ServiceFood / Pharma / Chemical
  • StandardASTM A240, AWWA D103
  • Service Life50+ years
Build Stainless Quote →
Material Systems

Three material specs. Matched to service.

Material selection drives service life more than any other decision. Match it wrong and you're refurbishing in five years. Match it right and the tank outlives the facility.

Spec · Water / Process

Fusion-Bonded Epoxy

Epoxy powder electrostatically applied and fused to carbon steel at 425°F. Reliable barrier at moderate cost. Workhorse construction for water, raw water, and process duty. Verify chemistry compatibility before specifying.

  • NSF 61 certified (potable variants)
  • Life expectancy: 20–30 years
  • pH range: 5 to 10
  • Not for digester or acidic service
Spec · Food / Dairy / General

Type 304 Stainless

Bolted austenitic stainless steel — no coating, no recoat, no degradation. Passive chromium-oxide layer is the protection. The default stainless choice for food, dairy, pharmaceutical, and clean industrial service.

  • ASTM A240 Type 304 / 304L
  • Life expectancy: 50+ years
  • Food-grade, FDA compliant
  • Not for chloride-bearing service
Spec · Aggressive / Chloride

Type 316 Stainless

Molybdenum-bearing stainless for chloride-rich, brine, biopharma, and aggressive chemical service. Higher first cost than 304 but the right call any time chloride pitting is a risk.

  • ASTM A240 Type 316 / 316L
  • Life expectancy: 50+ years
  • Biopharma, brine, chemical
  • Bolt & gasket selection critical
AWWA D103
Bolted carbon steel tanks for water storage
ASTM A240
Stainless plate / sheet specification
NSF 61
Drinking water system components
ASCE 7
Wind, seismic, and snow load design
OSHA 1910
Walking-working surfaces, ladders, fall protection
Frequently Asked

Answers before you submit.

Fusion-bonded epoxy is the right call for water, raw water, wastewater, and moderate-aggression process service where a 20–30 year service life is acceptable and first cost matters. Stainless is the right call when service chemistry (chlorides, low pH, food-grade, biopharma) demands it, when the lifecycle horizon is 50+ years, or when no recoat over the asset's life justifies the premium. The wrong call — FBE on a chloride-bearing chemical — is how tanks fail in five years.
304 is the default for food, dairy, pharma, and clean industrial service. 316 adds molybdenum, which provides meaningfully better resistance to chloride pitting and a wider chemical-compatibility window. The upgrade pays anywhere chlorides are present (brackish water, brine, seawater, deicing salt exposure, swimming-pool chemistry, certain pharmaceutical processes). If you're unsure, share the service chemistry and we'll spec it.
Instant pricing is order-of-magnitude — typically within ±15% of refined pricing for standard configurations on accessible sites. Variability comes from freight zone, foundation soil conditions, prevailing wage requirements, code complexity (seismic site class, wind speed, snow load), and current steel-market timing. Submission triggers a 24-hour refinement where our engineering team brings the number to a hard quote.
Yes. Every tank ships with PE-stamped foundation, shell, anchor, and accessory drawings. Stamps are state-specific — provide the project state and we'll route through the licensed engineer for that jurisdiction. Standard turnaround for full submittal package is two to three weeks after PO.
Both. We supply tank-only when you've got an erector under contract, and we supply erected when you want a single point of accountability. Coatings, foundations, dome covers, and accessories all bundle. Forensic spec review of existing tanks is also available as a standalone service.
FBE bolted tanks run 16–24 weeks after submittal approval depending on capacity. Stainless lead times depend on plate availability and run 20–28 weeks — longer if 316 plate is constrained in the steel market. We hold domestic carbon steel inventory, which keeps schedule risk lower than offshore-sourced competitors. Submit early if your in-service date is fixed.
Ready to spec?

One quote. Every line.

Configured tanks combine with metering, pumps, and aluminum covers in a single quote. Give us 24 hours and a project address.