Size a bolted steel digester, and see everything it drags along with it.
Diameter and height are the two numbers everyone starts with. They are also the two numbers that quietly set the boiler, the insulation package, the mixer count, the gas storage buffer, and the plate thickness at the bottom ring. Drag them here and watch all of it move together on a live 3D tank — before any of it is committed to a drawing.
What the tool returns
- Volume & flowWorking volume, gross shell volume, and feed rate at your retention time
- BiogasVolatile solids loaded, gas production, and the energy in it, on your feedstock's own conversion basis
- HeatFeedstock heating, envelope loss, peak demand, and boiler size with margin
- InsulationAn R-value target for your design low, and the heat it takes off the boiler
- MixingInstalled kilowatts, mixer count, and motor size for side-entry units
- Gas & structureDesign pressure, relief settings, storage buffer, and bottom-ring plate
- Shell materialStainless rings where the H₂S attacks, epoxy below, and what the mix costs
Size it in real time.
Drag the diameter and height, or add a ring and watch the tank grow. Every downstream requirement — heat, insulation, mixing, gas pressure, flow, and shell material — updates with it.
Drag to orbit · scroll to zoom
A digester asks for four things at once. Bolted steel is where they meet.
Digesters are corrosive, gas-tight, heated vessels that owners want built fast and often want to expand later. Those four demands are exactly where factory-coated bolted steel separates from cast-in-place concrete and field-welded steel.
Epoxy cured in a factory — or stainless, with no coating at all
Factory-applied thermoset epoxy is baked and holiday-tested on every panel before it ships. For the harshest headspace service — hydrogen sulfide, sulfuric acid at the gas–liquid line, biogenic corrosion — 304 or 316 stainless panels take the coating question off the table entirely, and the two can be mixed ring by ring.
No hot work, no cure time
Bolted erection is mechanical. There is no welding or grinding on site, no coating touch-up over weld seams, and no 28-day concrete cure in the schedule. A tank of the size above is typically erected in weeks rather than months.
Expandable when the feedstock grows
Panels unbolt. A bolted digester can be raised with an additional ring or relocated when a project is phased. Concrete and welded shells are permanent decisions made on day one, with day-one information.
Lighter foundation load
A steel shell weighs a fraction of a concrete wall of the same height, so the ring wall or slab carries mostly the liquid — lower foundation cost and fewer surprises on soft sites. See foundation systems.
Insulation and heating integrate cleanly
Rigid insulation and a metal weather jacket attach to the shell stiffeners. Internal or external heat exchangers, nozzles, manways, and side-entry mixer nozzles are factory-cut and reinforced — not core-drilled after the fact.
Gas-tight by design
Gasketed lap joints and sealed hardware make the shell suitable for low-pressure gas service. Bolted cone roofs and double-membrane gas holders both mount directly to the top ring.
| Decision | Bolted steel (factory coated) | Cast-in-place concrete | Field-welded steel |
|---|---|---|---|
| Erection time | Weeks; runs parallel with foundation cure | Months; forms, pours, cure | Weeks to months; weather-dependent |
| Corrosion protection | Factory-baked epoxy, holiday-tested per panel, or bare stainless | Liner or coating applied on site; crack-prone | Field blast and coat over weld seams |
| Headspace H₂S attack | Stainless upper rings and roof, epoxy below | Biogenic sulfuric acid etches concrete | Depends on field coating quality |
| Expansion / relocation | Add rings, unbolt, move | Not practical | Cut and re-weld; recoat |
| Site hazards | No hot work on a gas vessel site | Heavy forming, rebar, pumping | Welding and grinding on a gas vessel site |
| Foundation | Ring wall or slab; light shell load | Heavy; wall self-weight is large | Ring wall or slab |
Comparison reflects typical North American practice for anaerobic digestion service. Project conditions — seismic category, freight distance, local labor, and gas system scope — can change the ranking, which is what a lifecycle cost comparison is for.
What the designer is actually doing.
Every number on the panel comes from a handful of relationships that govern anaerobic digestion. Change one input and you can see which requirements move with it — and which ones do not.
What the model deliberately excludes
Seismic and wind design, snow load on the roof, foundation bearing capacity, freeboard for foam, gas train and flare sizing, digester gas cleanup, and anything about the site's electrical service. It also assumes a single continuously stirred vessel: staged digesters, external heat recovery loops, and thermal hydrolysis pre-treatment all change the heat balance materially.
Biogas yield is taken as a typical volatile-solids conversion and methane fraction for the feedstock you pick. Real yield depends on feedstock, co-digestion recipe, and how completely the tank is mixed — a number worth measuring on your actual substrate before it becomes a revenue assumption.
Where to take it next
Once the geometry is settled, the bolted tank configurator turns it into a budget proposal, a preliminary general arrangement drawing, and an editable CSI three-part specification. Insulation scope is detailed on tank insulation systems, the heating loop on heat transfer equipment, and the mixers and chopper pumps under metering, pumping & mixing.
What engineers ask when sizing a digester.
How big does an anaerobic digester tank need to be?
Why use a bolted steel tank for a digester instead of concrete?
How much heat does a digester need?
How much insulation does a digester tank need?
How much mixing power does an anaerobic digester need?
What gas pressure does a bolted digester roof handle?
Can I use these numbers in a design submission?
Send us the numbers. We'll turn them into a tank quote.
Copy the design summary from the panel above and send it over. We come back with a bolted steel digester proposal — epoxy-coated or stainless shell, cone roof or membrane gas holder, insulation, heating, mixing, and accessories — sourced and coordinated through our manufacturing partners, nationwide.
Already operating a digester and weighing a repair against a replacement? An inspection and condition assessment establishes what the existing shell has left, and why tanks fail covers the headspace corrosion modes that end most of them.